에어로솔 입자의 정밀입경분포 측정을 위한물분자 클러스터 이온의 질량예측

Mass Prediction of Various Water Cluster Ions for an Accurate Measurement of Aerosol Particle Size Distribution
  • 정종환; 
  • 이혜문; 
  • 송동근; 
  • 김태오

초록

For an accurate measurement of aerosol particle size distribution using a differential mobility analyser (DMA), anew calculation process, capable of predicting the masses for the various kinds of water cluster ions generated froma bipolar ionizer, was prepared by improving the previous process. The masses for the 5 kinds of positive and nega-tive water cluster ions produced from a SMAC ionizer were predicted by the improved calculation process. Thein good accordance with the experimentally measured ones, indicating that the improved calculation process aremore reasonable than the previous one in a mass prediction of bipolar water cluster ions.

키워드

Water cluster ions; Ion electrical mobility; Ion mass; Particle charging ratio
제목
에어로솔 입자의 정밀입경분포 측정을 위한물분자 클러스터 이온의 질량예측
제목 (타언어)
Mass Prediction of Various Water Cluster Ions for an Accurate Measurement of Aerosol Particle Size Distribution
저자
정종환; 이혜문; 송동근; 김태오
발행일
2007
저널명
한국대기환경학회지
권
23
호
6
페이지
752 ~ 759