상세 보기
Early Age Properties of HPC Columns under Construction-site Conditions
- Ying-wei Yun;
- 장일영
초록
High performance concrete (HPC) is widely used in civil engineering due to its high durability and low permeability etc. Compared with ordinary concrete, HPC may develop much higher AS (autogenous shrinkage) at early age due to the relative low water cement (w/c) ratio and adding of mineral admixtures, which is one of the main reasons for early age micro-cracking of HPC structures. This paper studies the early age property of HPC columns under similar construction-site surroundings by embedded strain transducers. Results show that for HPC structure, early-age autogenous shrinkage especially within the first day after concrete pouring is pretty large. AS within the first day are 60% larger than those for 14 days in this research for all specimens. Therefore it should be taken into account for structure durability. By comparison of PHPC (plain HPC column) and RHPC (reinforced HPC column) specimens, the effects of reinforced bars on AS and temperature distribution have been analyzed. Also the influence of w/c ratio on AS is demonstrated.
키워드
- 제목
- Early Age Properties of HPC Columns under Construction-site Conditions
- 저자
- Ying-wei Yun; 장일영
- 발행일
- 2008
- 권
- 2
- 호
- 1
- 페이지
- 63 ~ 68
- 언어
- ENG
- 출판사
- 한국콘크리트학회
- 발행국가
- 대한민국
- 분량
- 6 페이지
- ISSN
- E 2234-1315
P 1976-0485